Influence of a disinfectant based on polyhexamethylene guanidine hydrochloride on sanitary-indicatory microorganisms and on the white mice

Authors

  • С. Б. Передера
  • Ж. О. Передера
  • Н. С. Щербакова
  • Є. О. Держговська

DOI:

https://doi.org/10.31210/visnyk2017.03.19

Keywords:

PinaSept, polyexamethylene guanidine hydrochloride (PEMG-GCH), disinfectant

Abstract

The article presents the data relatively the analysis of the action of a disinfectant based on polyhexamethylene guanidine hydrochloride (PHMG-HC) on sanitary-indicatory microorganisms and on the white mice. We determined that a phenol coefficient of «PenaSept» in relation to S. aureus, E. coli is 7,4 and 5,9. Besides «PenaSept» shows a pronounced disinfectant activity. With a daily aerosol treatment for 14 days, the disinfectant is biosafety for the body of laboratory mice, which is proved on the basis of clinical and pathoanatomical studies.

Published

2017-09-28

How to Cite

Передера, С. Б., Передера, Ж. О., Щербакова, Н. С., & Держговська, Є. О. (2017). Influence of a disinfectant based on polyhexamethylene guanidine hydrochloride on sanitary-indicatory microorganisms and on the white mice. Scientific Progress & Innovations, (3), 91–93. https://doi.org/10.31210/visnyk2017.03.19

Most read articles by the same author(s)